ATCA System 300/40 Series- 14 Slot- DC- Dual Star- Radial IPMB

Description

Conforms to AdvancedTCA Standard PICMG 3.0 rev. 3.0
Input voltage -48 VDC/ -60 VDC- two redundant power entry modules (PEM)
Redundant hot-swap fan trays- airflow from bottom front to top rear; air filter access from front
300 W cooling capacity per slot at an ambient temperature of 55 °C
Prepared for two SCHROFF shelf managers with Pigeon Point ShMM 700
Shelf alarm panel (SAP) and shelf alarm display (SAD)
UL recognized- E229721 type T07